Version 3.00 Feb. 2019
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
26
8.1.2 MICR Operations by Specific Settings of Devices
Based on the setting of “Error ha
ndling options during Check insertion setting.”
in “Device Specific Settings” dialog box, operations, firing error events and
retune value differ considerably.
The differences by the settings of device specifications are indicated in the
following table.
(A) and (B) in the following table indicate:
(A)・・・ [Issue an Error Event for every error occurrence during Check insertion.]
(B)・・・ [Issue an Error Event for specified error occurrence during Check insertion.]
Operation Difference
(A) is marked (B) is marked
The read data
is normal
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by DataEvent.
DataEvent status is “0”
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by DataEvent.
DataEvent status is “0”
There is no
data to read
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_NODATA
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_NODATA
There is no notification by event.
Paper length is
illegal
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_BADSIZE
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_BADSIZE
There is no notification by event.