The data format
is illegal
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_CHECKDIGIT
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
When
“Fire ErrorEvent on check
digit parity error” check box in
“Device Specific Setting” dialog is
marked
, the result of data analysis
is notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_DIGITERROR
A part of the
data is not
analyzable
Or
Noise error is
occurred
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_BADDATA
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_BADDATA
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_DATAERROR
The cover is
opened during
insertion
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_COVEROPEN
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.
The paper is
jammed during
insertion
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_JAM
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.