EasyManua.ls Logo

ergoline SUN SELECT 1400 - Page 39

ergoline SUN SELECT 1400
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cleaning and maintenance
10/2013 1014906-00 Operating instructions – 37/76
In addition to the maintenance plan on page 36, the following items should be
checked to ensure safe operation and use of your tanning system.
Component Interval
1)
Activity
250 h / 3 months
500 h / 6 months
2500 h / 1 year
5000 h / 5 years
10000 h / 10 years
1 Springs X Inspect and replace as necessary
Springs X Replace
2 Bolts and fasteners of the canopy
hinge mechanism
X Inspect and replace as necessary
Bolts and fasteners of the canopy lift
mechanism
X Inspect and replace as necessary
Bolts and fasteners of the canopy
hinge/lift mechanism
X Replace
3 Bolts and fasteners of the base/tank
hinge/lift mechanism
X Inspect and replace as necessary
Bolts and fasteners of the base/tank
hinge/lift mechanism
X Replace
4 Cylinders X Inspect and replace as necessary
Cylinders X Replace
5 Chassis and associated fasteners X Inspect and replace as necessary
Chassis and associated fasteners X Replace
6 Wiring and associated plugs / termi-
nal connections
X Inspect and replace as necessary
7 Acrylic panels
2)
X Inspect and replace as necessary
Acrylic panels
2)
X Replace
8 Acrylic support(s) X Inspect and replace as necessary
Acrylic support(s) X Replace
9 High pressure filter glass X Inspect and replace as necessary
High pressure filter glass X Replace
10 High pressure lamp holder X Inspect and replace as necessary
High pressure lamp holder X Replace
1) Interval must be repeated after each inspection or replacement
(i.e. 1st: 3 months, 2nd: 6 months, 3rd: 9 months, etc.)
2) The schedule for acrylic replacement listed refers only to the condition of
the acrylic relating to safety and does not address the efficacy of UV
transmission.

Table of Contents

Related product manuals