Cleaning and maintenance
10/2013 1014906-00 Operating instructions – 45/76
7.8.3 Starter
Replace faulty starters immediately.
You can recognize a faulty starter by the blackened ends of the lamps or
when the lamps can no longer be started.
Operating a lamp with a faulty starter significantly shortens its service life. The
lamp loses power and may begin to flicker under certain circumstances.
The starters are located in either one of the two lamp sockets or are visible
when the lamps are removed.
Turn 90° and carefully remove from the socket.
7.8.4 High pressure lamps and filter panels
UV high pressure lamps are used in the facial tanner and the shoulder tanner.
CAUTION!
Danger of overheating will exist if the wrong
UV high pressure lamps are used!
The danger of overheating will exist if the wrong UV high
pressure lamps are fitted in the shoulder tanner. The device
might be damaged.
Never interchange the UV high pressure lamps used in
the facial tanner with those used in the shoulder tanner!
WARNING!
Fire hazard due to overheated lamps!
Non-approved high pressure lamps can explode. Hot lamp
components can set other parts on fire. People can be killed
or severely injured due to smoke inhalation and fire.
Only fit the high pressure lamps specified by the manu-
facturer.
Clean the inside of the device regularly. Dust particles
are flammable!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ergoline SUN SELECT 1400 and is the answer not in the manual?

ergoline SUN SELECT 1400 Specifications

General IconGeneral
Brandergoline
ModelSUN SELECT 1400
CategoryPersonal Care Products
LanguageEnglish

Related product manuals