EasyManua.ls Logo

Ericsson RX1290 - Network, SNMP, and Alarm Outputs; High Speed Data Over Ethernet Output; SNMP Remote Control Connector; Alarm Connector Specifications

Ericsson RX1290
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
B.5.3.2 High Speed Data over Ethernet
This connector is located at the back of the unit using the RJ-45 Ethernet port and is
enabled through the license key (RX1290/SWO/HSETHER).
Table B.26 High Speed Data Over Ethernet Connector
Item Specification
Safety status SELV
Connector Type RJ-45 (100BaseT)
Connector designation 10/100BaseT
Data rates (bit/s) 5 Mbps
Standards ETSI EN 301 192 v.1.2.1 (1999-06), Section 4
De-encapsulation type Data-Piping (Proprietary)
B.5.4 SNMP Remote Control Connector
Table B.27 SNMP Control Connector
Item Specification
Safety status SELV
Connector type RJ-45 (100BaseT)
Connector designation 10/100BaseT
Standard Ericsson SNMP Control MIB
B.5.5 Alarm Connector
Table B.28 Relay Alarm Output Specification
Item Specification
Safety status SELV
Connector type 9-way D-type female
Connector designation: ALARM
Contact Configuration SPDT (Change-over)
All volt-free contacts, fully isolated.
Contact Rating 1 A at 24 V DC
1 A at 50 V AC
Maximum Switching Current 1 A
Maximum Switching Voltage 50 Vdc / 30 V AC
EN/LZT 790 0003/2 R1A
B-21