EasyManua.ls Logo

Ericsson RX1290 - Alarm and Serial Data Outputs; Alarm Connector and Relay Details; RS-232 Data Output Specification

Ericsson RX1290
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing the Equipment
1 5
6 9
2.7.9 Alarm Connector and Relay
The alarm relay connector has a summary relay. The
summary relay is activated whenever the unit detects an
alarm, or the power is switched off.
Table 2.11 Alarm Connector
ALARM RELAY
Item Specification
Connector type
9-way, D-type, Female for the summary alarm
relay
Connector
designation
ALARM RELAY
Pin-outs Pin 1 - Open
Pin 2 - Open
Pin 3 - Open
Pin 4 - Relay 1, common pin
Pin 5 - Open
Pin 6 - Open
Pin 7 - Open
Pin 8 - Relay 1, Normally Closed (Open on
Alarm)
Pin 9 - Relay 1, Normally Open (Closed on
Alarm)
1 5
6 9
2.7.10 RS-232 Low-speed Asynchronous Data Output
A 9-way, D-type female connector provides a asynchronous
low-speed data serial communications interface. The status
of the data output on this connector is given in the Data
Menus (Menus 3.4 and 3.5).
Table 2.12 RS-232 Low-speed Data
DATA
Item Specification
Connector type 9-way, D-type, Female
Connector
designation
RS-232 Data Out
Standards RS-232 DATA
Configuration DCE
Pin-outs
Pin 1 - Reserved
Pin 2 - Receive Data Output (RxD) (RS-232)
Pin 3 - Reserved
Pin 4 - No connection
EN/LZT 790 0003/2 R1A