Operating the Equipment Locally
3.9 Setting Up the Transport Stream Output (Menu 5)
3.9.1 Set-Up Procedure
Use Table 3.37 to step through the Transport Stream Output set-up procedure using
Menu 5. This allows the Transport Stream for the current Service to be output on the
ASI output connectors.
Table 3.37 Setting Up the Transport Stream Output (TSO)
Step Action Result
1
Go to Menu 5 to enter the
TRANSPORT STREAM OUTPUT
setting.
Press Edit then select one of the
following:
POST INPUT (i.e. as input
Transport Stream);
POST TS DESCRAMBLE (i.e.
post TTV, RAS descrambling);
POST ES DESCRAMBLE (i.e.
post TTV, RAS, Common
Interface, BISS, DIRECTOR
descrambling).
The Transport Stream Output will be formatted
according to the choice made.
2 Press Save to store the choice. The Transport Stream Output (TSO) is now set.
3.9.2 Setting the Output Connector
Use Table 3.38 to step through the Connector configuration procedure using Menu
5.1.
Table 3.38 Setting Up the Output Connector
Step Action Result
1
Go to Menu 5.1 to enter the
Connector configuration.
Edits the Connector output function for BNC
connectors 1, 2 and 3.
2
Press Edit then select one of the
following, for each connector:
DISABLED
ASI
HD SDI
SD SDI
AUTO
The Connectors output will be formatted
according to the choice made.
3 Press Save to store the choice. The Connector output is now set.
EN/LZT 790 0003/2 R1A