EasyManua.ls Logo

Ericsson RX1290 - Environmental Conditions; Operational and Storage;Transportation Conditions

Ericsson RX1290
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
Item Specification
Maximum Switching Power 24 W / 60 VA
Minimum Switching Load 0.1 mA, 100 mV DC
B.6 Environmental
B.6.1 Conditions
Table B.29 Environmental Conditions
Operational Specification
Temperature 0°C to +50°C ambient air temperature with free air-flow
Humidity 0% to 95% (non-condensing)
Cooling requirements Convection cooling/free air-flow
Handling/movement Fixed (non-mobile) use only
Storage/Transportation
Temperature -20°C to +70°C (-4°F to +158°F)
Humidity 0% to 95% (non-condensing)
B.7 Compliance
8
B.8 Safety
This equipment has been designed and tested to meet the requirements of the
following:
EN 60950-1 European Information technology equipment - Safety.
IEC 60950-1
International Information technology equipment - Safety.
UL 60950-1
USA Information Technology Equipment - Safety.
8
The version of the standards shown is that applicable at the time of manufacture.
EN/LZT 790 0003/2 R1A