EasyManua.ls Logo

Ericsson RX8000 Series - Page 47

Ericsson RX8000 Series
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2
2.7.11 DATA OUT Connector
A data output interface may be used with either RS232 or
RS422 connector, as described below.
Table 2.12 DATA OUT Connector
Item Specification
Connector type 9-way, D-type, female
Connector designation DATA OUT
Pin RS232 RS422
Pin-outs Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
NC
TxD
RxD
NC
NC
NC
CTS
(RTS)
NC
HSD_CLK_A
NC
NC
NC
NC
HSD_CLK_B
NC
HSD_DATA_A
HSD_DATA_B
DATA OUT
2.7.12 ALARM Connector
All units provide an alarm relay connector supplying a
summary relay. Under user configuration, it is activated
whenever the unit detects an alarm, or the power is
switched off.
Table 2.13 ALARM Connector
ALARM RELAY
Item Specification
Connector type 9-way, D-type, female
Connector designation ALARM
Pin-outs Pin 1 – Relay 1, Normally Closed
Pin 2 – Relay 2, Common
Pin 3 – Relay 1, Common
Pin 4 – Relay 3, Common
Pin 5 – Relay 1, Normally Open
Pin 6 – Relay 2, Normally Closed
Pin 7 – Relay 2, Normally Open
Pin 8 – Relay 3, Normally Closed
Pin 9 – Relay 3, Normally Open
EN/LZT 790 0005 R1A
2-15

Table of Contents

Related product manuals