26
GB
6.2 ERROR MESSAGES
Diagnostics are made on switching on and during
normal operation.
If the instrument detects an error condition the
display will show:
LME:
ErrErr
ErrErr
Err” in the lower display and the code
which identifies the type of error in the
upper display.
LDE:
EE
EE
E” and the error code.
The complete list of all the possible errors follows
in numerical order.
Some errors automatically reset the instrument: if
the error persists, send the instrument to your
supplier to be checked.
6.3 LIST OF POSSIBLE ERRORS
100100
100100
100 EEPROM writing error.
Consult your supplier.
2xx2xx
2xx2xx
2xx Error in the configuration parameters.
The two less significant figures indicate
the number of the incorrect parameter
(e.g.
209 Err209 Err
209 Err209 Err
209 Err indicates error of
parameter P9).
Press SMT and FUNC, then set the
parameter correctly.
See section 4.
301301
301301
301 RTD input calibration error.
Contact your supplier.
305305
305305
305 TC input calibration error.
Contact your supplier.
307307
307307
307 RJ input calibration error.
Contact your supplier.
400400
400400
400 Error in the operative parameters.
To deal with the problem, enter the
predefined parameters (“Default
Parameters”, see section B), pressing
pushbuttons t and s at the same
time.
Then set the operative parameters.
500500
500500
500 Auto-zero error
Contact your supplier.
502502
502502
502 RJ error
Contact your supplier.