58
Table 6-8. Descriptions for SO Command
Syntax Description
SO
<nn>
command is used to select the reference impedance for dBm
calculation.
<nn>
is a two-digit decimal numeric number from “00” to “20”,
representing 21 different types of reference impedance.
Example: Command string “SO15” to set reference impedance at 600.
nn Impedance nn Impedance nn Impedance
00 2 07 110 14 500
01 4 08 124 15 600
02 8 09 125 16 800
03 16 10 135 17 900
04 50 11 150 18 1000
05 75 12 250 19 1200
SO<nn>
06
93 13 300 20 8000