87
7-5-3 Command Summary of SCPI
Command Parameter Std/New Explanation
ABORT Std Event, no query
CONFigure[:SCALar] Std
Configure meter to perform specified
measurement.
:CURRent
New Set the current measurement.
:AC
[<numeric value>]
[[,@1]|,@2]
New
:ACDC
:DCAC
[<numeric value>]
[,@1]
New
:DC
[<numeric value>]
[[,@1]|,@2]
New
:DIOCtest
New
Set the primary display to diode with the
continuity test.
:FREQuency
[[,@1]|,@2]
New Set the meter to frequency measurement.
:FUNCtion?
[[,@1]|,@2] New
Query the measuring function.
:OFFDual
New Turn off the 2ND display.
:OFFRecord
New Turn off the dynamic recording mode.
:RANGe
Std Set the measuring range.
:AUTO
<Boolean>[,@1] New
:AUTO?
[[,@1]|,@2] New
:DIRection
<UP|DOWN>
[[,@1]|,@2]
New
:RANGe?
[[,@1]|,@2] New
Query the measuring range.
:RESistance
New Set the resistance measurement.
[:2W]
[<numeric value>]
New
:VOLTage
New Set the voltage measurement.
:AC
[<numeric value>]
[[,@1]|,@2]
New
:ACDC
:DCAC
[<numeric value>]
[,@1]
New
:DC
[<numeric value>]
[[,@1]|,@2]
New