Mute level setting
MTLV>***
This sets the volume when it is muted.
o By default, the setting is −∞dB.
−∞dB
The volume becomes −∞ dB when muted.
−20dB
The volume is reduced 20 dB from the set level when muted.
Remote control AMP button setting
AMPRM>***
Set whether the remote control AMP section buttons are enabled or
disabled.
o By default, the setting is ON.
o When using this unit connected to an ESOTERIC integrated ampli-
fier or preamp, set this to OFF.
ON
This enables the INPUT (l/;), SETUP, VOLUME (+/−) and MUTE
buttons in the AMP section of the remote control.
o Use the above SETUP and INPUT (l/;) buttons to set the L/R
balance (BAL>) and input gain (LVL>) (page24).
OFF
This disables the INPUT (l/;), SETUP, VOLUME (+/−) and MUTE
buttons in the AMP section of the remote control.
o Use MENU1 to change L/R balance (BAL>) and input gain
(LVL>) settings.
Remote control input (RS-232C) connector
setting
RS232C>***
Set this to ON only when using the remote control input (RS-232C)
connector.
o By default, the setting is OFF.
OFF
The remote control input (RS-232C) connector cannot be used.
ON
The remote control input (RS-232C) connector can be used.
Trigger signal output setting
TRIG_O>***
o By default, the setting is OFF.
OFF
Do not output trigger signals.
ON
Output trigger signals.