PRINCIPLES OF OPERATION
The lythium batteries used by Estrima to equip Birò are sealed rechar-
geable lythium polimers, with a BMS inside (Battery Management Sy-
stem) for the continous monitoring and the balance of the cell voltages.
The batteries are supplied with a built-in Data Logger designed to record
all faults and unintended battery use. The Data Logger is an analysis
instrument intended to monitor the battery parameters over time.
The Data Logger is mainly used to keep the battery under control. The
main measurements it records are:
- vehicle operating cycles;
- battery discharge voltage;
- battery operating temperatures;
- energy absorption.
In contrast to the lead-acid batteries or other technologies, the Estrima
lythium batteries do not require special restrictions on use, operation
and management.
IMPORTANT: remove the key from the vehicle when it is not
in use. If the key stays in the ON position over 12 consecutive
hours, the battery may be damaged irremediably.