Pn004.0 Stop Mode
[0] Stops the servomotor by applying DB and then
releases DB.
[1] Coast to a stop.
[2] Stops the servomotor by DB when servo OFF,
stops the servomotor by plug braking when overtravel,
then places it into coast (power OFF) mode.
[3] Makes the servomotor coast to a stop state when
servo OFF, stops the servomotor by plug braking
when overtravel, then places it into coast (power OFF)
mode.
[4] Stops the servomotor by DB when servo OFF,
stops the servomotor by plug braking when overtravel,
then places it into zero clamp mode.
[5] Makes the servomotor coast to a stop state when
servo OFF, stops the servomotor by plug braking
when overtravel, then places it into zero clamp mode.
Pn004.1 Error counter clear mode
[0] Clear error pulse when S-OFF, do not when
overtravel.
[1] Do not clear error pulse.
[2] Clear error pulse when S-OFF orovertravel
(excep for zero clamp)
Pn004.2 Reference pulse form
[0] Sign + Pulse
[1] CW+CCW CW + CCW
[2] A + B (×1)
[3] A + B (×2)
[4] A + B (×4)
Pn004.3 Inverses pulse
[0] Do not inverse PULS reference and SIGN reference.
[1] Do not inverse PULS reference; Inverses SIGN
reference.
[2] Inverse PULS reference;Do not inverse SIGN
reference.
[3] Inverse PULS reference and SIGN reference.
Pn005.0 Torque feedforward form
[0]Use general torque feedforward, external
analog(Tref) feedforward input is invalid.
[1]Use general torque feedforward, external
analog(Tref) feedforward input is valid.
[2]Use high-speed torque feedforward, external
analog(Tref) feedforward input is invalid.
[3]Use high-speed torque feedforward, external