ProNet Plus Series AC Servo User's Manual
Pn512.2CN1_17
Pn512.3CN1_18
Pn513.0CN1_19
Bus control input
terminal enabled
It is used to set input port filter time. The signal will be
lagged if the parameter setting is too high.Unit:0.2ms
It is used to set alarm port filter time, The signal will be
lagged if the parameter setting is too high.Unit:0.2ms
Input port signal
inversion
[0]: Do not inverse signal.
[1]: Inverse signal
Pn516.0CN1_15 inversion
Pn516.1CN1_16 inversion
Pn516.2CN1_17 inversion
Pn516.3CN1_18 inversion
Pn517.0CN1_19 inversion
Input port signal
inversion
Motor dynamic brake time Unit: ms
Serial encoder error
time
In the range of this parameter, there will be no warning
of serial encoder error Unit: 0.1ms
This parameter set position complete time Unit: 0.1ms
Pn521.0 If connected externally regenerative resistor
0: connect externally regenerative resistor between B1
and B2
1: Dose not connect externally regenerative resistor,
relay on internal capacitance.
(This parameter is in effect only on
ProNet-A5/01/02/04)
Pn521.1 Reserved
Pn521.2 Reserved
Pn521.3 Reserved
When load percentage is larger than overload alarm
threshold, A04 will occur soon.
Pn525 is recommended to set below 120, otherwise
the servo drive and motor will be damaged.
Unit:%
Temperature
threshold of motor
overheat alarm
When servomotor winding temperature exceeds
Pn526 setting, A19 will occur. Unit:℃
(Only enabled in ProNet–75/1A/1E/2B)