31 | Technical Data
ETAS ES582.2 | User Guide
5.10 Electrical Data
5.10.1 Voltage Supply
5.10.2 CAN Interface (CAN1 and CAN2)
Operating voltage range 4.75 to 5.25 V DC
Max. current consumption 0.35 A
Overvoltage category
(mains supply, IEC 60664-1)
II
CAN1 and CAN2 2 independent interfaces,
isolated from the USB port,
each channel can be configured sepa-
rately.
Standard ISO 11898-1, ISO 15765-4,
ISO 11898-2:2015
Protocols CAN V2.0a (standard identifier),
CAN V2.0b (extended identifier)
CAN FD
(ISO/CD 11898-1:2015; Bosch CAN FD SIC
Specification V1.0 [Non-ISO])
Transmission speed High-speed CAN/ CAN FD SIC header:
max. 1 Mbaud at 20 m bus length
CAN FD SIC (data): max. 5 Mbit/s (operat-
ing temperature range)
CAN FD SIC (data): max. 8 Mbit/s (room
temperature)
Controller ARM Cortex MCU
Transceiver (physical layer) TJA1462BT