    What to do if measurements are not being started on ETAS Recording Equipment?
    • P
      pperezAug 4, 2025
      If measurements are not starting with your ETAS Recording Equipment, first update the module's firmware using HSP. Then, verify that your measurement setup meets all requirements and that the cabling connecting the hardware to your PC is both correct and intact. Finally, check the 'ER' LED for blinking, as this could indicate that the baud rate is unsupported by the module.
  • K
    karen16Aug 13, 2025
    How to fix ETAS Recording Equipment driver installation issues?
    • M
      Mary MartinezAug 13, 2025
      If your computer doesn't install the drivers when you first connect the ETAS Recording Equipment module, start by checking if the module is listed in the Windows Device Manager. If not, try using a different USB port on your computer. As a next step, restart your PC. Finally, make sure you're logged in with administrator rights, as these are required to install the driver.
  • A
    Allison HawkinsAug 23, 2025
    Why is the ES581.4 module not found in ETAS Recording Equipment?
    • A
      Anna MccoyAug 23, 2025
      If the ES581.4 module of your ETAS Recording Equipment isn't found when using 'Search for hardware', first, ensure that the installed INCA version and INCA ES5xx Add-On version meet the necessary requirements. Next, verify with HSP that the required firmware is installed on the module. Lastly, check to make sure the cabling is intact.

Summary

General Information

Basic Safety Instructions

Provides information on safety notices, general safety, and user/operator requirements.

Getting Started

Preparation

Covers initial steps for installation, including drivers, system requirements, and CD-ROM contents.

Installation Sequence

Details the required order for installing the ES581.4 drivers and connecting the module.

ES581.4 USB Drivers Installation

Step-by-step guide to installing the ES581.4 USB drivers.

ES581.4 J2534 Drivers Installation

Guide for installing the ES581.4 J2534 drivers, including license agreement.

USB and CAN Connection

Instructions for connecting the ES581.4 via USB and establishing CAN network connections.

Troubleshooting Problems

Common Problems and Solutions

Lists common issues, diagnostic questions, and possible solutions for the ES581.4.

Module Not Found and Measurement Issues

Addresses issues like module not being found and measurement failures.

Technical Data

System Requirements (Hardware)

Details the necessary PC hardware, operating system, and driver prerequisites.

Pin Assignment

Details the pinout of the ES581.4 DSUB connector for CAN connections.

Ordering Information

ETAS Contact Addresses

ETAS HQ and Support

Provides contact details for ETAS headquarters, subsidiaries, and technical support.

ETAS ES581.4 Specifications

General IconGeneral
ModelES581.4
ManufacturerETAS
InterfacesCAN FD, Ethernet, USB
Operating Temperature-40°C to +85°C
USBUSB 2.0
Power SupplyVia USB
Operating Voltage5 V
Current ConsumptionApproximately 500 mA
Ethernet100BASE-T