ES581.4 - User’s Guide 31
ETAS Technical Data
5 Technical Data
The “Technical Data” chapter contains a summary of the pin assignments and all
technical data of the ES581.4 CAN Bus Interface USB Module.
5.1 General Technical Data
5.1.1 Fulfilled Standards and Norms
The module meets the following standards:
5.1.2 Environmental Conditions
5.1.3 Maintenance of the Product
Do not open or change the module housing! Work on the module may only be
performed by qualified personnel. Return defective modules to ETAS for repair.
5.1.4 Cleaning the Product
We recommend cleaning the product with a dry cloth.
Standard Test
EN 61326-1 Electrical equipment for measurement,
control and laboratory use - EMC
requirements
EN 61000-6-2 Immunity (for industrial environments)
EN 61000-6-3 Interference emissions (living area,
business and commercial areas as well
as small enterprises)
EN 60529 Degree of protection through housing
(IP code)
EN 60068-2-32 Environmental testing - Part 2: Tests;
Tested: free falling
Operating temperature range -40 °C to +70 °C
-40 °F to +158 °F
Storage temperature range -40 °C to +85 °C
-40 °F to +185 °F
Relative humidity 15% to 95%, non-condensing
Operating altitude max. 5,000 m / 16,400 ft
Degree of protection IP42