Navis 100 Installation Guide 21
Maintenance
WARNING: Disconnect the luminaire from all cables and
allow it to cool before performing any cleaning and
maintenance.
AVERTISSEMENT : Débrancher le projecteur de tous les
bles et laisser le refroidir avant d’effectuer un nettoyage ou
un entretien.
CAUTION:
Check for excessive dust or debris in the heat-
dissipating fins around the entire luminaire enclosure. Clean
using compressed air or a soft cloth. Keeping the components
of the enclosure clean facilitates efficient cooling and extends
LED longevity.
NEVER spray liquids into the luminaire.
NEVER spray compressed air into a luminaire that is
powered-up.
A can of compressed air or oil-free air from an air compressor set at a low
setting can be used to blow through the vent holes and remove dust or
other debris. Dust buildup can cause overheating and premature
shutdown.
All components can be cleaned using compressed, oil-free air as
described above or a clean micro-fiber cloth. The use of any liquid
cleaning solution is not recommended.
Inspect all mounting hardware for wear and, if necessary, clean using
compressed, oil-free air or a soft, lint-free cloth.
See the installation manual for your driver for information about servicing
the driver.
Specifications
Designed for use with an F-Drive series driver or other Class 2 or
Low Voltage Limited Energy (LVLE) power supply (48 VDC maximum)
Ideal for short/medium throw
Recessed/flush mount
Single-axis tilt (30° maximum) and 360° rotation
Beam angle options: 15°, 25°, 40°, 60°
White or RGBW LED options
Fade to Warm option (3000 K white only)