Locking the user interface
After you have set up the fixture, you can lock the user interface to prevent
additional changes.
Step 1: Hold the Up and Down buttons simultaneously for 3 seconds.
The display will show
 to indicate that the user interface
is locked.
Step 2: To unlock the user interface, hold the Up and Down buttons
simultaneously for 3 seconds.
Updating the fixture software
ETC recommends using UpdaterAtor software to manage software updates.
For more information on UpdaterAtor, see the UpdaterAtor Software Quick
Guide, which you can download for free from www.etcconnect.com.
When you add a ColorSource fixture running a newer software version or
update a ColorSource fixture to a newer software version using UpdaterAtor,
you can use that fixture to push the newer software version to all connected
ColorSource fixtures.
You can push newer software versions from a connected fixture only on
ColorSource fixtures running software v1.3.0 or newer. Use UpdaterAtor to
update individual fixtures running versions older than v1.3.0.
Step 1: Remove power and DMX from the master fixture that is
running the software version that you want to push to other
fixtures.
Step 2: Hold the Up and Down buttons simultaneously while restoring
power.
Step 3: The display will show
 to indicate the update mode
is selected.
Step 4: Press the Mode button to start the update process.
The display will alternate between
 and the
percentage complete while updating.
The master fixture will reboot once the update is
complete.
Restoring factory defaults
Hold all three buttons (Mode, Up, and Down) simultaneously for five seconds.
The DMX start address will blink once to confirm that defaults have been
restored.