ETC Quick Guide
Source 4WRD II Version 1.1.2
Connect Cables
You can control the fixture using AC power or DMX. Configure the fixture to
use the appropriate control method on the user interface. See
Configure the
Fixture on the facing page
.
WARNING: Do not use or store the Source 4WRD II fixture
below 5°C (41°F). When the fixture has been stored or
transported in cold temperatures, allow it to warm to room
temperature for a minimum of 1 hour before applying power.
Applying power to a cold fixture will cause damage to the fixture
and void ETC warranty.
Note:
For optimum performance, make sure that your dimmer is out
of regulated mode. See Line-dimming on the facing page for
recommended dimmer settings.
Note:
Connecting both power and data from a SmartBar 1 to a
Source 4WRD II fixture may cause flickering.
1. If you are using DMX control: Connect one RJ45 data cable for data-in
and one for data-thru, as needed. Use the strain relief at the bottom of
the fixture to support the data cables.
To order an RJ45-to-female XLR adapter, use ETC part number
W6538.
To order an RJ45-to-male XLR adapter, use ETC part number
W6539.
2. If you are using DMXcontrol and this is the last fixture in the line,
terminate the fixture with a 120Ohm resistor. Please contact your ETC
customer service representative to purchase ETC part number N4086.
3. Connect the fixture to the power source.
Source 4WRD II Page 6 of 8 ETC