23
2096580-16-11/22 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-A-.5
EN
12.3. Actuator CES-A-BBA/CES-A-BCA
Ì Cube-shaped design 42x25mm
Ì CES-A-BCA suitable for use in aggressive media (e.g. acids, alkalis)
Ì In combination with read head CES-A-LNA…/CES-A-LCA…
Dimension drawing for CES-A-BBA
CES-A-B 071840
25
ø8
ø4,5
42
32
±0,1
12
4,6
Active face
Active face
2 safety screws M4X14
included
Dimension drawing for CES-A-BCA
42
32
± 0,10
25
31
48
4,5
8
212
4,6
Active face
Active face
2 safety screws M4X14
included
Flat seal
NOTICE
CES-A-BCA: The at seal provided must be used during assembly.
12.3.1. Technical data
Parameter
Value
Unit
min. typ. max.
Housing material
- CES-A-BBA Fortron, reinforced thermoplastic, fully encapsulated
- CES-A-BCA PE-HD plastic without reinforcement, fully encapsulated
Flat seal material (CES-A-BCA only) Fluororubber 75 FPM 4100
Dimensions 42x25x12 mm
Weight 0.02 kg
Ambient temperature
°C- CES-A-BBA -25 - +70
- CES-A-BCA -25 - +50
Degree of protection IP67/IP69K
Installation orientation Active face opposite read head
Power supply Inductive via read head