27
2084606-19-09/17 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety System CES-A-AEA-02B/CES-A-AEA-04B
EN
11.5. Read head CES-A-LCA-…
Ì Cube-shaped design 42x25mm
Ì PE-HD plastic housing material, suitable for use in aggressive media (e.g. acids, alkalis)
Dimension drawing
32
42
48
25
31
l
12
14
4,6
8
4,5
± 0,1
Active face
Active face
Two M4x14 safety screws
included
Flat seal
NOTICE
The at seal provided must be used during assembly.
Typical operating distance
With evaluation unit CES-A-AEA-… and actuator CES-A-BCA
NOTICE
For a side approach direction for the actuator and read head, a minimum distance of s=3mm must
be maintained so that the operating distance of the side lobes is not entered.
Terminal assignment
Read head with connection cable
H11
H12SH1
BN
WH
Shield
View on the plug
connector of the
read head
Evaluation unit
CES-A-AEA-…
Read head
Approvals
X
20
15
10
5
20
15
10
5
5
10
15
20
Y
Z