54
Group B switches No CT coil attached CT coil
DIP-switch number and
position
Illustration
Station Max Current
Facility/
house Max
Current per
phase
1 2 3 4 5
16 A
3-phase
32 A
1-phase
0 0 1 0 1
invalid 25 A 160 A
1 0 1 0 1
invalid 26 A 180 A
0 1 1 0 1
invalid 27 A 200 A
1 1 1 0 1
invalid 28 A invalid
0 0 0 1 1
invalid 29 A invalid
1 0 0 1 1
invalid 30 A invalid
0 1 0 1 1
invalid 31 A invalid
Any dierent conguration than the ones presented above is considered invalid and
causes an error state.
English
Install and congure either CT coils or HEMS, not both. If both are installed and congu-
red, only the lower current setting gets applied.