EasyManua.ls Logo

EverFocus EPA6220 - 3 OSD Menu Tree

EverFocus EPA6220
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPA6220 / EPA6236
8
3. OSD Menu Tree
No.
Main Menu
1
st
Layer
2
nd
Layer
3
rd
Layer
1 System
2 Dome
Comm
Device ID
Check ID
Target ID
1-250
Soft Protocol
Auto
Baud Rate
1200, 2400, 4800, 9600
Comm Reset
Save
Exit
IR Display
Working Mode
Auto, Off, On
Testing Time
2-15 sec.
Output Power
40%, 60%, 80%, 100%
Illumination On
1-15
Ambient Light
0-50
IR Switch Zoom
1-10
Exit
Guard Tours
Guard Tour
1-8
Setting
ID (1-16), Point, Time, Speed
Init
Running
Delete
Exit
A-B Scan
Preset A
0-64
Preset B
0-64
Scan Speed
1-64
Dwell Time
2-60 sec.
Running
Delete
Exit
PAN Scan
PAN Scan Speed
1-64
Init
Running
Exit
Pattern
Pattern No
1-4
Setting
Running
Delete
Exit
Park Action
Park Mode
Off, AB Scan, 360, Home, Tour1, Pattern1
Park Time
1-60 min.
Setting
Call