Multifunctional Machine ER2500- THE OPERATOR’S
MANUAL
- 25
-
ATTENTION
Weekly check the oil level.
Every 50 working hours change the oil.
-Position an appropriate container under the lower cap on the back of the tank,
remove the cap and let the content flow.
-Clean and put back the lower cap.
-Fill up the tank with new oil.
-Start the engine for some minutes, then turn it off and check the oil level, add oil if
necessary.
-Screw in the upper cap.
Never start the engine with an empty tank.
For the type of oil to use, see the chart: RECOMMENDED LUBRICANTS.
4.7 ELECTRIC CIRCUIT
The machine has an electric wiring scheme that must be checked before any work on
the wiring.
4.7.1 BATTERY
-It is located on the back both sides under the engine compartment bonnet.
-Check periodically that the level of the electrolyte is 10-15mm over the upper edge
of the plates (for batteries with maintenance). Otherwise, restore the level with
distilled water.
-Never use acids that may damage the battery, but only use distilled water. Keep the
battery dry and clean to avoid harmful dispersion of electricity.
-If the machine remains unused for a long time, take the battery to a dry place and
recharge it every month.
ATTENTION
The battery contains corrosive acid. Avoid the contact with skin,eyes and suits. In case
of contact, abundantly wash with water.