The operational parameters are defined in the Hypermotion mode of the Remote Panel, in
the LCD secondary menu.
Operational Parameter Value Range Default Value
# Blocks 1 to 4 1
Pre-Roll from 00s00fr to 5s00fr 00s00fr
PGMSpeed 50, 100, 200, 300, 400,1000% 100
2nd Lever +/- 1000%, 0-1000% +/- 1000
Specific Behavior of Remote Panel Keys
• RECORD: Pressing this key while the current block is recording does not send any
command to the camera.
• RECORD: The Remote beeps if the CAM key refers to an empty block.
• TAKE: This key is operational in ARM mode.
• CLEAR: This key has no effect.
Cue Points Management
• When a new ARM/REC command is issued on a block, all its cue points are cleared.
• If the Last Cue command cannot access the desired TC preroll, the player remains on
the current cue point.
• If the Last Cue command refers to a TC that does not exist anymore, the player
jumps to the beginning of the current memory block.
• Cue points can not be marked when working on several memory blocks.
3.3.7. Vision Research Camera
Camera Names
The Vision Research cameras are also sold under the following product names:
• Vision Research
• X-Mo
• Superloupe
• Antelope
• Sprintcam
USER MANUAL Multicam LSM 12.05 Hypermotion Cameras
3. Operation 29