10
CAHB-20 series
10
3.2 Operating voltages
and limits
Theoperatingvoltagesandthelimitsforstandardversion,
including when PWM is used for speed ramp up refer to:
E design: 12 V DC version: supply voltage
• Foractuator:12VDC±20%
• ForEncoder:4to20VDC
• ForPotentiometer:Voltagelimitedbypower2W
• Forabsoluteanalogpositionsensor:10to55VDC
(current consumption 15 mA max.)
E design: 24 V DC version: supply voltage
• Foractuator:24VDC±10%
• ForEncoder:4to20VDC
• ForPotentiometer:Voltagelimitedbypower2W
• Forabsoluteanalogpositionsensor:10to55VDC
(current consumption 15 mA max.)
E design: 48 V DC version: supply voltage
• Foractuator:40to55VDC
• ForEncoder:4to20VDC
• ForPotentiometer:Voltagelimitedbypower2W
• Forabsoluteanalogpositionsensor:10to55VDC
(current consumption 15 mA max.)
S design: 12 V DC version: supply voltage
• Foractuator:9to16VDC
• Forextending/retractingcommand:5to55VDC(current
consumption 1 mA max.)
• For0~5Vabsoluteanalogpositionoutput:8to27VDC
(current consumption 15 mA max.)
• For0~10Vabsoluteanalogpositionoutput:13to27VDC
(current consumption 15 mA max.)
S design: 24 - 48 V DC version: supply voltage
• Foractuator:18to55VDC
• Forextending/retractingcommand:5to55VDC(current
consumption 1 mA max.)
• For0~5Vabsoluteanalogpositionoutput:8to27VDC
(current consumption 15 mA max.)
• For0~10Vabsoluteanalogpositionoutput:13to27VDC
(current consumption 15 mA max.)