3.0 Technical data
9
NOTE
Thetechnicaldata(dimensions,weight,output,connectionvalues
etc.) can be found in the enclosed drawings and data sheets ( 11
Appendix, page 37).
3.1 Operating conditions
Environment
Information Value Unit
Temperature range 40to+85 °C
Relativeatmospherichumidity,
maximum (no build up of condensation)
up to 96 %
NOTE
• Below 0 °C: load capacity and speed will decrease
• Above 40 °C: temperature of the motor will increase and the duty
cycle and running time could be decreased
12 V DC version – Duration (intermittent)
Information Value Unit
Maximum operating time without a break 85 sec.
Maximunbreakuntilnextoperation,
9 time of operating time
765 sec.
Maxdutycycleatratedload:10%(85son/765so)
E design : 24 & 48 V DC version
S design : 24 & 48 V DC version – Duration (intermittent)
Information Value Unit
Maximum operating time without a break 85 sec.
Maximumbreakuntilnextoperation,
4 time of operating time
340 sec.
Maxdutycycleatratedload:20%(85son/340so)