Page #12 background imageLoading...
Page #12 background image
11
040112XX
ZSME400000004
EXCELL PRECISION CO., LTD
FNC Group function setting
Item
Function
Setting value
Default
Parameter
Description
FNC-01
Digital Filter I
0
5 Hz
4
1
4.17 Hz
2
2.5 Hz
3
2.08 Hz
4
1.25 Hz
5
1.04 Hz
6
0.63 Hz
7
0.52 Hz
8
0.31 Hz
9
0.26 Hz
FNC-02
Digital Filter II
0
Disabled
2
1
Less filter
Greater
2
3
4
5
FNC-03
Key Locked
000000
111111
0
Normal
(lock disable)
The bits and front
panel key
positions are
related to each
other
000000
1
Close
(lock enable)
FNC-04
“F” function setting
Parameter Description
0 Display Net / Gross weight
1 Setpoint parameter setting
2 Tare reset
3 Manual serial, parallel print output
4 Start load
5 Stop load
6 Start comparison
7 Unload command
8 Totalise weight and counts
command
9 Clear totalised weight and counts
10 Hold mode
11 Escape Hold mode(I / O DSP)
12 Convert to Gross / Net / totalised
weight / totalised Count
1
FNC-05
“F1” function setting
0