Troubleshooting
ProblemPossibleCauseCorrectiveAction
1.Fuseisblown.
1.Replacefuse.Checkcoilresistance,
batterycharge,chargingsystem,and
wiringconnectionsandreplaceif
necessary.
2.Lowvoltagesupplyattheclutch.
2.Checkcoilresistance,batterycharge,
chargingsystem,andwiringconnections
andreplaceifnecessary.
3.Damagedcoil.
3.Replaceclutch.
4.Inadequatecurrentsupply.4.Repairorreplaceclutchleadwireor
electricalsystem.Cleanconnector
contacts.
Clutchwillnotengage.
5.Rotor/armatureairgapistoolarge.
5.Removeshimorreplaceclutch.