Brew Pressure Adjustments
time consuming and since it is very
close to the electrical connection on the boiler
we recommend that all adjustment are
done when the machine is not plugged in.
Note: We recommend that the Rotary pump be set to 9
he OPV should be set to open at 11
Adjust the pump pressure by loosening the lock nut then
turning the adjustment screw. Turn the adjustment screw clockwise to raise the pressure
ise to lower the pressure.
Turn the adjustment screw counter clockwise to lower the
pressure and clockwise to raise it. Betw
lower the lever on the brew
group to release the pressure. Make your adjustment with the machine unplugged and
then plug it in and test your setting. When you have the pressure adjusted
le holding the adjustment screw
in place or it may turn and change the setting.
We set this before your machine has shipped. To set the OPV
will have to run the machine with the backflush disc in place. First
adjustment screw on the OPV
so that it just starts to
let water flow out of the over
tube. It is now set to open at 11