CARAT
14
Additional handling of the machine
Changing the group gasket
CLEANING AND CARE
Remove and insert the porta-filter gently.
Never use excessive force to try to close the
porta-filter.
To remove the porta-filter, use a
straight-blade screwdriver to release
the shower by prying down with
medium force.
Remove the filter basket(A), then
place the new gasket and shower(B)
into the porta-filter(C).
Remove the shower and gasket.
Preheat the gasket to soften the rubber. A - heat the gasket for 15 seconds
using the water from the hot water outlet, or B - place the gasket, shower,
and porta-filter in hot water for 30 seconds.
Remove and discard the old gasket.
Insert the new gasket (chamfer and
EXPOBAR logo facing up) into the
shower.
Important:
Avoid placing wet cups directly on the
cup shelf, it may drip into the machine
and cause machine damage.
01
04
02
05
03
15s
30s
99
O
C
A
A
B
C
B
> 65
O
C