CARAT
9
INSTALLATION AND START UP
Positioning
Electrical installation
Install the machine on a level surface. Adjust the feet to
ensure that it dispenses coffee evenly in all of the cups.
Select a level, dry, strong and stable installation surface at
least 110 cm off the floor.
Leave enough space above and behind the machine to
ensure easy cleaning and maintenance.
Do not install the machine whilst wet or damp. If wet or
damp, leave the machine until completely dry then ask
service personnel to check that none of the electrical
components are affected.
Note:
Leave an air gap of approximately 30 cm above the
machine and 10 cm behind it to ensure ventilation.
i
The coffee machine should only be connected to the power supply by qualified
personnel. The following safety instructions should be followed at all times:
Check that the electrical specifications on the ratings plate match the specifications of
the power supply at the point of installation.
The coffee machine must be connected to an earthed socket that complies with the
regulations in force in the country of installation.
You should protect the electric line of the installation with a circuit breaker switch
appropriated for the power consumption of the machine, specified on its ratings plate.
A residual current circuit breaker must be installed in accordance with the
characteristics of the area of the installation.
Check the characteristics, power rating of the system and that the diameter of the
cables are suitable for the power used by the machine.
Do not connect the coffee machine to the power supply via extension boards, adapters
or shared sockets.
The manufacturer will not be held liable for damage to persons, animals or
property resulting from incorrect installation of the coffee machine.
DANGER!
If the mains cable or plug is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid SERIOUS INJURY OR DEATH!
Connection types
Connect the machine as per the instructions on the ratings plate.
Machine: Machine:
Supply hose
Supply hose
Supply
380Vac 3Ph+N
Supply
230Vac Ph+N
380Vac 3Ph230Vac Ph+N
Brown
Blue
Blue
Grey
Black
Brown
NEUTRAL
NEUTRAL
PHASE
PHASE
PHASE
PHASE
Yellow/Green
Yellow/Green
MIN. 10 cm
MIN. 30 cm