23
Elen
R
CLEANINg AND CARE
Additional handling of the machine
Remove and insert the porta-filter gently.
Never use excessive force to try to close
the porta-filter.
Important:
Avoid placing wet cups directly on the
cup shelf, it may drip into the machine
and cause machine damage.
Changing the group gasket
To remove the porta-lter, use
a straight-blade screwdriver to
release the shower by prying
down with medium force.
Remove the lter basket(A),
then place the new gasket and
shower(B) into the porta-
lter(C).
Remove the shower and
gasket.
Preheat the gasket to soften the rubber. A - heat the gasket
for 15 seconds using the water from the hot water outlet, or
B - place the gasket, shower, and porta-lter in hot water for 30
seconds.
Remove and discard the old
gasket. Insert the new gasket
(chamfer and EXPOBAR logo
facing up) into the shower.
01
04
02
05
03
15s
30s
99
O
C
A
A
B
C
B
> 65
O
C