Section 3 Pilot’s Operating Handbook
Emergency Procedures EXTRA 500
3-68 26. January 2011
Land as soon as practical
3 BLEED OVERTEMP r
This warning means the temperature switch in the duct
supplying the pressure cabin with bleed air has detected a
temperature exceeding limits for the composite structure and
windshield.
WINDSHIELD; Push
TEMP CTRL; Check AUTO
TEMP CTRL Rheostat; 13°
If no effect:
TEMP CTRL; MANUAL
WARM/COOL; COOL
Hold for 10 seconds
If no effect and warning light still illuminates:
Warning
When
ENV AIR is OFF cabin will lose pressurization.
ENV AIR; OFF
Emergency Descent; Perform to safe
altitude (< 10,000 feet)
PRESS; DUMP
4 Impending Skin Panel or Window Malfunction
PRESS; DUMP
Emergency Descent; Perform to safe
altitude (< 10,000 feet)