Section 4 Pilot’s Operating Handbook
Normal Procedures EXTRA 500
4.6.e Engine Start
Note If TOT is above 100°C prior to engine start, use the ENGINE
MOTORING
switch to lower it. Observe starter limits, see
2.16.a -2.
Item Condition
NIGHT/DAY TEST
FUEL TRANSFER
LEFT
and RIGHT
Check both ON
FUEL PUMP 1 or 2
ON
Fuel Pressure Check reading > 10 psi
TOT Check reading < 100 °C
ENGINE MOTORING
Check NORMAL
ENGINE START
Momentary START
At 12 to 15 % N1 is reached:
Item Condition
Condition Lever Fully forward
TOT Monitor < 850 °C
Note After passing through 58 % N
1
starter will deactivate
automatically.
Item Condition
Oil Pressure Check indication
OIL PRESS
Check extinguished
Propeller RPM
Check positive indication
at 25% N1
PNEUMATIC LOW
Check extinguished
4-16 26. January 2011