Section 2 Pilot’s Operating Handbook
Limitations EXTRA 500
2.17.d Airstart Envelope Limits
At altitude 25.000 feet or below:
- Begin inflight starting procedure within l minute after engine
shutdown
(Power lever: “flight idle”)
- Airspeed range for restart: 100 up to 140 KIAS
2.17.e Structural Temperature/Color Limitation
- Minimum Structural component temperature: -54 °C (-65 °F)
- Maximum Structural component temperature:
+72 °C (+161.6 °F)
Note Not to exceed the maximum temperature limit, color
specification for composite structure (manufacturer
document EA-05205.19) has to be complied with.
2.17.f Maximum Passenger Seating Limits
Refer to regulations of national authority.
The number of passengers on board is limited by the approved
seating configuration installed but must not exceed five (5)
persons. Airplane weight and balance limits have to be
considered.
2.17.g Limitations for Electrothermal Anti-ice Devices
Maximum operating time of propeller heat without running
engine is: 10 seconds.
Maximum operating time of pitot-, static- and stall heat on
ground (test function) is: 10 seconds.
Caution Do not operate pitot-, static- and stall heat during flight at
OAT above +20 °C (68 °F).
2-26 26. January 2011