P6
P2
P6
P2
13
TECHNICIAN MENU
RESET PART HOURS
CONTROLS PROCEDURE
Press P6 and SET CLOCK will appear.
Press P2 several times until TECHNIC SET is displayed.
Press P6.
Hold key P4 down to reach the reserved code "A0"
When the code has been reached, conrm by pressing P6
"GENERAL DATA" will appear
Press P2 until RESET PART HOURS is displayed.
Enter pressing P6
Hold key P4 down to reach code "77" and conrm with P6.
"DONE" will be signalled on the display to conrm the command
UNLOCK
CONTROLS PROCEDURE
Press P6 and SET CLOCK will appear.
Press P2 several times until TECHNIC SET is displayed.
Press P6.
Hold key P4 down to reach the reserved code "A0"
When the code has been reached, conrm by pressing P6
"GENERAL DATA" will appear
Press P2 until UNLOCK is displayed.
Enter pressing P6
Hold key P4 down to reach code "77" and conrm with P6. Hold key P1
down until the alarm signal disappears.
GENERAL DATA
TECHNIC SET
CODE A0
RESET PART HOURS
GENERAL DATA
TECHNIC SET
CODE A0
UNLOCK