20
ULTRAWATT CARTRIDGE
The ign-plug is just a heating resistor: once powered, it can develop a temperature that allows
to cause a ame.
DEPRESSION CONTROL CIRCUIT BOARD
This sensor develops the depression inside the appliance. Any anomaly will be signalled on the
display.
DEBIMETER
This sensor develops the depression inside the appliance. Any anomaly will be signalled on the
display.
BULB THERMOSTAT
The bulb thermostat is a mechanical safety device for temperature that acts as a switch: if
the temperature is lower than the value at which the thermostat is calibrated, the contact
remains closed allowing passage of the current. If the temperature exceeds the value set in the
thermostat, the contact opens and must be restored manually after having analysed the cause
of the event.
There are two types of thermostat:
set at 85°C
set at 100°C: it intervenes whenever the temperature of the tank rises excessively.
TEMPERATURE PROBE
The temperature sensor is available in dierent lengths in relation to use.
MECHANICAL PRESSURE SWITCH
the pressure switch is a mechanical safety device that controls the depression
AIR PRESSURE SWITCH
the digital pressure switch controls the depression
MICRO SWITCH
The micro switch is a device that is used in some products as a safety device or as a limit switch
indicator.
A SMALL PHOTOGRAPHIC KEY, ACCOMPANIED BY A BRIEF DESCRIPTION, HAS BEEN REALISED TO EASE RECOGNITION OF THE ELECTRIC COMPONENTS.
ATTENTION!!! THE COMPANY RESERVES THE RIGHT TO REPLACE COMPONENTS WITH OTHERS HAVING EQUAL OR IMPROVED
FEATURES WITHOUT PRIOR NOTICE!
WE RECOMMEND REFERRING TO THE EXPLODED VIEWS AVAILABLE AT OUR WEBSITE FOR SPARE PART REQUESTS!!!
COMPONENTS

Related product manuals