COMFORT PLUS INSTALLATION
Chapter 4
Air inlet from the environment
To allow air recirculation an air inlet point
must be envisioned, which is preferably
positioned in the lower part of the structure
in order to favour convection. The air must
be withdrawn from the machines working
environment.
Hot convection air
The heat accumulated inside the
covering must be vented to prevent
excessive over-heating of the insert
Forced ventilation
The tangential fan distributes the
heat developed by the insert into the
environment.
To protect from any over-heating, the Comfort Plus is supplied with a probe that analyses the temperature
inside the structure and intervenes by reducing the functioning power.
From the clearance measurements of the stove given in the technical features, it is necessary to consider
at least 50 mm of air in the upper part and on the 2 sides.
The  ue outlet pipe must always maintain a minimum distance of 50 mm from in ammable
parts.