ROOM THERMOSTAT
Chapter 6
Open contact thermostat D the stove switches o or stays o showing STBY on display D1.
This function can be suspended temporarily by pressing key 1:
If from STBYD the stove will remain o alternatively showing STBY”, OFF and current time on the
display D1.
If from T ON D the stove switches o alternatively showing T ON”, OFF and current time on the
display D1.
To go back to using the function, press button 1 again.
To de nitively exclude the function just raise the temperature of the stove thermostat using button 3.
MECHANICAL THERMOSTAT FUNCTIONING FOR DUCTING MOTOR CONTROL
The connection of an external thermostat will allow to separate the insert functioning from the functioning
of the ducting motor.
At this point just set the desired temperature, the mechanical thermostat will control the functioning of
the second motor:
with temperature to be reached the second motor will follow the progress of the stove
when the temperature is reached it will take the 2nd motor to 1st speed, making the relative luminous
indicator on the control board  ash.
ATTENTION!!!
Using the external room thermostat in the various modes, in automatic the day-night
temperature function is disabled.