27
PRODUCT FUNCTIONALITY
Chapter 5
Display D1 will show the current time, the hours ashing while the minutes are xed: use keys 2 and 3 to 5.
adjust the time and then con rm using key 5.
At this point the hours will become xed and the minutes will start to ash: use keys 2 and 3 to adjust 6.
the minutes.
To go back to selection of the hours, press button 4 again or escape and con rm using button 1.
FUNCTIONING CYCLE
BASIC INSTRUCTIONS
The stove you have purchased uses pellet fuel. This type of material is obtained from natural waste from
the machining of wood. By means of a special process that does not require the use of any binding agent
and additive, the waste is compressed in industrial machinery under high pressure and they become solid
wooden pellets.
IT IS PROHIBITED to burn non-pelletised raw materials inside our stoves. The failure to comply with these
prescriptions voids all guarantees and could jeopardise the safety of the appliance.
The following recommendations must be followed the rst two or three times the stove is ignited:
It is possible that slight odours are produced due to the drying of the paints and silicones used. Do not
remain in the environment for long periods.
Do not touch the surfaces as they could still be unstable.
Air the room well several times.
The hardening of the surfaces is terminated after several heating processes.
This appliance must not be used to burn waste.
SWITCHON
Before switching the stove on the following points must be veri ed:1.
the feed-box must be full of pellets
the combustion chamber must be clean
The brazier must be completely free and clean
check the hermetic closure of the re door and the ash drawer
make sure the power supply cable is connected correctly
the bipolar switch in the rear right part must be positioned on 1
Press button 1 for 3 seconds: display D1 will show “2. AT 08” decreasing by one number every second.
In the phase the appliance performs self-analysis to check the functionality of each individual
electric component. When this cycle has been completed, display D1 will show “AC 15” (these are the
minutes when the stove attempts the ignition phase and decreases by 1 every minute that passes).
The rst time the product is used, even if the feed-box is full, there is the possibility that the pellets
are not distributed into the combustion chamber for the rst 15 minutes. This is because the pellet
feed worm screw is empty. If no ame has developed in the stove after 15 minutes D1 will show “NO
ACC”.