The adjustment is made on a percentage basis, and therefore any change of this parameter leads
to a proportional variation on all loading speeds of the stove.
To access the percentage adjustment of pellet feeding, you have to enter the user programming
by pressing button 3, and while keeping it pressed, press button 5.
At this point use button 5 to move through the menu until you see “ut F” flashing on D2.
If you go beyond this parameter unintentionally, exit by pressing button 1 and repeat the
procedure.
The value “00” will be shown on D1: using buttons 2 and 3, you can set an increased/decreased
percentage at 5 point intervals (the parameter can be modified with a maximum scale from -50 to
+50).
Adjustment table
LACK OF
PELLETS
Increase the percentage by 5 percent and try the stove with this new
setting for at least half an hour. If the problem is reduced but not
resolve
d, increase by a further 5 percent. Repeat this process until
the problem is resolved.
If the problem cannot be resolved, contact the service centre.
EXCESS PELLETS
Decrease the value by 5 percent and try the stove with this new
setting for at least half
an hour. If the problem is reduced but not
resolved, decrease by a further 5 percent. Repeat this process until
the problem is resolved.
If the problem cannot be resolved, contact the service centre.
When the final adjustment has been made, press button 1 to confirm and exit the program.
14.3 AUTOMATIC CLEANING SCHEDULE FOR SPRINGS
Display D1
Display D2
Function
08:00 ut G Automatic cleaning start time
22:00 ut H Automatic cleaning end time
These two parameters make it possible to set the time period within which the automatic cleaning
of the springs is active.
To access these parameters, press button 3 and hold it down, then press button 5.
When you have entered the user parameters, use button 5 to move through them until display D2
shows "ut G".
Parameter G (D2=ut G; D1=Es. "08:00")
Use buttons 2 and 3 to set the start of the time period in which automatic cleaning is active. To
confirm and continue with programming, press button 5.
Parameter H (D2=ut H; D1=Es. "22:00")
Use buttons 2 and 3 to set the end of the time period in which automatic cleaning is active. To
confirm and continue with programming, press button 5.
At this point, the automatic cleaning is disabled during the times not included within the period of
time set.