60 60
Max. overall thermal power kW 25.0 25.0
Max. useful thermal power kW 23.0 23.0
- output air power kW 3.4 3.4
- output water power kW 19.6 19.6
Min. useful thermal power kW 4.5 4.5
- output air power kW 0.5 0.5
- output water power kW 4.0 4.0
Min. hourly fuel consumption kg/h
5.0 5.0
Tank capacity kg ~ 43 ~ 43
Recommended chimney draught Pa ~ 10 ~ 10
Chimney draught at max useful power Pa 12 12
Chimney draught at min useful power Pa 10 10
Rated electrical power W 350 350
Rated voltage Vac 230 230
Rated frequency Hz 50 50
Water inlet/outlet pipe diameter “ 1 1
Automatic discharge pipe diameter “ 1/2 1/2
Pump head m 4 4
Max accepted working water power bar 1.5 1.5
CO measured at max useful power % 0.011 0.011
CO measured at min useful power % 0.042 0.042
Efficiency at max useful power % 92.5 92.5
Efficiency at min useful power % 89.8 89.8
Exhaust gas temp. at max useful power °C 148.3 148.3
Exhaust gas temp. at min useful power °C 84.8 84.8
Mass of gases emitted at max useful power
g/s 16.43 16.43
Mass of gases emitted at min useful power
g/s 11.23 11.23
Tests using wooden pellets as fuel, with heating power equal to 4.9 kWh/kg.
The data stated above is a reference and not binding. The manufacturer reserves the right to carry
out any modifications in order to improve the performance of the product.