4-23
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
X5#
= Verbosemode 0=clear/none(defaultforTelnetconnection)
1=verbosemode(defaultforRS-232/RS-422connection)
2=taggedresponsesforqueries
3=verbosemodeandtaggedforqueries
N
If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command does
(for example, the read matrix name command
E
CN
}
,returnsIpn•
X3)]
).
X5$
= Flowcontrol hardware, software, none (only the first letter required)
X5%
= Datapacing(inmsbetweenbytes) 0000(default)-1000
X5^
= Time(in10-msincrements)towaitforcharacters 10(=100ms,default)-32767
X5&
= Time(in10-msincrements)towaitbetweencharacters 2(=20ms,default)-32767
X5*
= Porttimeoutinterval(in10-sec.increments) 1(=10seconds)-65000(defaultis30=300seconds=5minutes)

Table of Contents