Matrix Software, cont’d
CrossPoint / MAV Matrix Switchers • Matrix Software
5-10
Sync Time to PC button
Clicking the Sync Time to PC button causes the computer you are operating to
send its internal time to the switcher in a set time command.
GMT (offset) field
TheGMTelddisplaystheamountoftime,inhoursandminutes,thatthelocal
timevariesfromtheGMTinternationaltimereference.Ifnecessary,adjustthe
offset as follows:
1. ClickintheGMTeld.Asetoffseteldappearswiththeoffset
intheformat±HH:MM(–12:00to+14:00). The graphic cursor
becomes a text cursor in the set offset field.
2. Edit the field as desired to set the proper offset. Leading zeroes are optional.
Sometimezonesareonthehalf-hour(30minutes).
3. PresstheTabkeyonthekeyboardorclickinanothereldtoexitthesetoffset
field.
4. Click the Take button to make the offset change take effect.
Use Daylight Savings checkbox
Click in the Use Daylight Savingscheckbox.WhenDaylightSavingTimeisturned
on,theswitcherautomaticallyupdatesitsinternalclockbetweenStandardTime
andDaylightSavingTimeinthespringandfallonthedatethatthetimechange
occursinthecountryorregionselected.WhenDaylightSavingTimeisturnedoff,
the switcher does not adjust its time reference.
Administrator Password field
TheAdministratorPasswordelddisplaysthepasswordrequiredtologontothe
CrossPointorMAVswitcherviatheLANportwithalloftheadministrator’srights
andprivileges.Passwordsarecasesensitiveandarelimitedto12upper-caseand
lower-case alphanumeric characters.
While you are logged on as a user, this field is masked with asterisks (************) as
a security measure.
N
Editing the Administrator Password field while connected via the LAN port can
immediately disconnect the user from the switcher. Extron recommends editing
this field using a serial port and protecting the Ethernet access to this screen by
assigning an administrators password to qualified and knowledgeable personnel
only.
N
The following characters are invalid in passwords:
{space} + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
Edit this field as follows:
1. ClickintheAdministratorPasswordeld.Thegraphiccursorbecomesatext
cursor.
2. Edit the case-sensitive password as desired.
3. PresstheTabkeyonthekeyboardorclickinanothereldtoexitthe
AdministratorPasswordeld.
4. Click the Take button to make the password change take effect.