7.3.4.7. Install the top rail and plug the top of the 1-1/2” square x 42-7/16”
long closure post in the same manner as a standard picketed guard
closure. FIG. 7.8 shows the installation at this stage.
7.3.4.8. Attach a second 2” x 4-1/8” tie strap to the second hole from the top
of the 1-1/2” square x 42-7/16” long closure post using a
5/16”-18 x 2-1/4” long hex bolt, 5/16”-18 locknut, and 5/16” flat
washers oriented as shown (FIG. 7.9), then attach tie straps to the
adjacent platform angle post in the platform extender using
5/16”-18 x 1” long hex bolts, 5/16”-18 locknuts, and 5/16” flat washers
oriented as shown.
7.3.4.9. Tighten all fasteners securely.
FIG. 7.8
FIG. 7.9

Table of Contents