B680H 25 732719 - Rev.D
Translation of the original instructions
ENGLISH
In brackets, the effects on the other inputs when the pulse is active
LOGIC “CA” PULSES
AUTOMATED
SYSTEM STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens and closes
after the pause
time
no effect
no effect
(opening inhibited)
no effect
opens and closes
after the pause
time
no effect
WHEN OPENING
no effect
closes
immediately after
opening is com-
pleted
blocks
operation
no effect no effect
closes
immediately after
opening is com-
pleted
OPEN IN PAUSE
resets pause time closes
blocks
operation
resets pause time
(closing inhibited)
resets pause time
closes when
disengaged
WHEN CLOSING
immediately
reverses to
opening
no effect
blocks
operation
reverses to
opening and clo-
ses after pause
time
immediately
reverses to
opening
immediately re-
verses to opening
BLOCKED
opens and closes
after the pause
time
closes
no effect
(opening and clo-
sing inhibited)
no effect
(closing inhibited)
opens and closes
after the pause
time
no effect
(closing inhibited)
LOGIC “C”
MAINTAINED COMMANDS
PULSES
AUTOMATED
SYSTEM STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens no effect
no effect
(opening inhibited)
no effect no effect no effect
WHEN OPENING
/ no effect
blocks
operation
no effect no effect no effect
OPEN
no effect
(closing inhibited)
closes
blocks
operation
no effect
no effect
(closing inhibited)
no effect
(closing inhibited)
WHEN CLOSING
immediately
reverses to
opening
/
blocks
operation
blocks
operation
blocks
operation
blocks
operation
BLOCKED
opens closes
no effect
(opening and clo-
sing inhibited)
no effect
(closing inhibited)
no effect
(closing inhibited)
no effect
(closing inhibited)
Tab. 1/g
Tab. 1/h